Pubblicazioni

Echocardiographic Quantification of Superior Vena Cava (SVC) Flow in Neonates: Pilot Study of Modified Technique  (2022)

Autori:
Ficial, Benjamim; Corsini, Iuri; Bonafiglia, Elena; Petoello, Enrico; Flore, Alice Iride; Nogara, Silvia; Tsatsaris, Nicola; Groves, Alan M
Titolo:
Echocardiographic Quantification of Superior Vena Cava (SVC) Flow in Neonates: Pilot Study of Modified Technique
Anno:
2022
Tipologia prodotto:
Articolo in Rivista
Tipologia ANVUR:
Articolo su rivista
Lingua:
Inglese
Formato:
Elettronico
Referee:
Nome rivista:
DIAGNOSTICS
ISSN Rivista:
2075-4418
N° Volume:
12
Numero o Fascicolo:
2083
Intervallo pagine:
1-11
Parole chiave:
MRI; Phase-contrast MRI; SVC flow; cerebral blood flow; doppler; echocardiography; neonate; perfusion; preterm; systemic blood flow
Breve descrizione dei contenuti:
Ultrasound Superior Vena Cava (SVC) flow assessment is a common measure of systemic and cerebral perfusion, although accuracy is limited. The aim of this study was to evaluate whether any improvements in accuracy could be achieved by measuring stroke distance from the instantaneous mean velocity, rather than from peak velocity, and by directly tracing area from images obtained with a high frequency linear probe. Paired phase contrast magnetic resonance imaging (PCMRI) and ultrasound assessments of SVC flow were performed in a pilot cohort of 7 infants. Median postnatal age, corrected gestation and weight at scan were 7 (2-74) days, 34.8 (31.7-37.2) weeks 1870 (970-2660) g. Median interval between PCMRI and ultrasound scans was 0.3 (0.2-0.5) h. The methodology trialed here showed a better agreement with PCMRI (mean bias -8 mL/kg/min, LOA -25-+8 mL/kg/min), compared to both the original method reported by Kluckow et al. (mean bias + 42 mL/kg/min, LOA -53-+137 mL/kg/min), and our own prior adaptation (mean bias + 23 mL/kg/min, LOA -25-+71 mL/kg/min). Ultrasound assessment of SVC flow volume using the modifications described led to enhanced accuracy and decreased variability compared to prior techniques in a small cohort of premature infants.
Pagina Web:
https://doi.org/10.3390/diagnostics12092083
Id prodotto:
130492
Handle IRIS:
11562/1078908
ultima modifica:
23 febbraio 2023
Citazione bibliografica:
Ficial, Benjamim; Corsini, Iuri; Bonafiglia, Elena; Petoello, Enrico; Flore, Alice Iride; Nogara, Silvia; Tsatsaris, Nicola; Groves, Alan M, Echocardiographic Quantification of Superior Vena Cava (SVC) Flow in Neonates: Pilot Study of Modified Technique «DIAGNOSTICS» , vol. 12 , n. 20832022pp. 1-11

Consulta la scheda completa presente nel repository istituzionale della Ricerca di Ateneo IRIS

<<indietro

Attività

Strutture

Condividi