Publications

Hydroxyapatite/collagen composite is a reliable material for malar augmentation  (2016)

Authors:
D'Agostino, Antonio; Trevisiol, Lorenzo; Favero, Vittorio; Gunson, Michael J; Pedica, Federica; Nocini, Pier Francesco; Arnett, G. William
Title:
Hydroxyapatite/collagen composite is a reliable material for malar augmentation
Year:
2016
Type of item:
Articolo in Rivista
Tipologia ANVUR:
Articolo su rivista
Language:
Inglese
Referee:
No
Name of journal:
Journal of Oral and Maxillofacial Surgery
ISSN of journal:
0278-2391
N° Volume:
74
Number or Folder:
6
Page numbers:
1238.e1-1238.e15
Keyword:
Adolescent; Adult; Collagen; Cone-Beam Computed Tomography; Durapatite; Female; Humans; Male; Maxillary Osteotomy; Maxillofacial Prosthesis Implantation; Middle Aged; Orthognathic Surgery; Surgery, Plastic; Young Adult; Zygoma
Short description of contents:
Purpose To evaluate the long-term results of cheekbone augmentation using porous hydroxyapatite granules mixed with microfibrillar collagen in a large group of patients. Materials and Methods Four hundred thirty patients who underwent zygomatic augmentation and intermaxillary osteotomy were evaluated clinically, radiologically, and histologically. Results Complications were found in 13 patients (1.56%). There were no relevant radiologic differences in prosthesis volume after 1 month (T1) or after 24 months (T2) in any patient; there were no clinically relevant differences in 110 patients after 36 months. At T1, the prosthesis had a granular structure and the granules had not migrated; at T2, the prosthesis was staunchly adhering to the underlying bone. Over time, the radiopacity of the material increased. Histologic results of 19 biopsy specimens obtained from 8 patients 2 years after the procedure showed prominent ossification with low inflammation, confirming new bone formation over time. According to the visual analog scale, the patients were generally satisfied with the aspects that were considered. Conclusion Hydroxyapatite and collagen composite used during malarplasty produced a successful outcome. Its main drawback is a learning curve that is longer than for more frequently used implantable biomaterials.
Product ID:
96678
Handle IRIS:
11562/959829
Last Modified:
November 11, 2022
Bibliographic citation:
D'Agostino, Antonio; Trevisiol, Lorenzo; Favero, Vittorio; Gunson, Michael J; Pedica, Federica; Nocini, Pier Francesco; Arnett, G. William, Hydroxyapatite/collagen composite is a reliable material for malar augmentation «Journal of Oral and Maxillofacial Surgery» , vol. 74 , n. 62016pp. 1238.e1-1238.e15

Consulta la scheda completa presente nel repository istituzionale della Ricerca di Ateneo IRIS

<<back

Activities

Research facilities

Share